To bigger review, click picture here.
Split EV DC Charge Pile
2018/3/31 22:42:06 Viewers:
- BrandNET OEM ODM
- TypeNET-90kW-750Vdc
Introduction
| SPLIT EV DC CHARGE PILE | |||||||||
| SYSTEM ADVANTAGE | |||||||||
| Customerized design for centered EV charge stations, performing fast, efficient and high power charging EV. | |||||||||
| The DC charger composed with rectifier and outdoor charge terminals, max fixing 25 rectifier module to a standard | |||||||||
| cabinet. Widely installed to EV charge stations, enterprise private parking lots. | |||||||||
| Split DC charger input DC voltage range 200-700V, max output power 360kW. | |||||||||
| Modular design: Rectifier module includes 3phase active power filter, starting charger transiently, | |||||||||
| Perfect ventilation channel design. | |||||||||
| Integrated with rectifying, control, output and calculation. | |||||||||
| Comprehensive protection against AC input over-voltage, under-voltage, output over-voltage, under-voltage, | |||||||||
| over-temperatuer, over-load, battery reverse, high current shock/surge suppression. | |||||||||
| TECHNICAL SPECIFICATION | |||||||||
| EV charge pile Power (Rated kW) | NET-60kW-450VDC | NET-90kW-450Vdc | NET-150kW-450Vdc | NET-180kW-450Vdc | |||||
| NET-60kW-750Vdc | NET-90kW-750Vdc | NET-150kW-750Vdc | NET-180kW-750Vdc | ||||||
| AC INPUT | |||||||||
| Input volt (Vac) | 323-475Vac (3Ph+N(GND) | ||||||||
| Input current (A) | <110 | < 160 | <200 | < 300 | |||||
| Input frequency (Hz) | 45 - 65Hz | ||||||||
| Efficiency | > 95% | ||||||||
| Input power factor | > 99% | ||||||||
| THDi | < 5% | ||||||||
| OUTPUT | |||||||||
| Output voltage range | 200Vdc ~ 450Vdc (450Vdc design model) | ||||||||
| 200Vdc ~ 750Vdc (750Vdc design model) | |||||||||
| Rated output current(A) | 150 | 225 | 300 | 375 | |||||
| 80 | 120 | 160 | 200 | ||||||
| Max output current(A) | 165 | 245 | 330 | 400 | |||||
| 88 | 134 | 176 | 220 | ||||||
| Soft-start time(S) | 3 ~8 | ||||||||
| Output constant current range(A) | 10% ~ 100% | ||||||||
| Voltage precision | < + 0.2% | ||||||||
| Current precision | < + 0.2% | ||||||||
| Ripple percentage(max) | < 1% | ||||||||
| Unbalance rate(Output in average-current) | < + 3% (load level: 50% ~ 100%) | ||||||||
| Noise(1m) | < 65dB | ||||||||
| PROTECTION | |||||||||
| Output short-circuit | When output current retracted to nominal +40% range, charger recovers automatically | ||||||||
| Output over-voltage | Cut-off output, charger will not recover automatically, manual re-start it. | ||||||||
| Input over/under voltage | Cut-off output, charger recovers when voltage lowers to normal range | ||||||||
| Phase lost | Cut-off output, charger recovers when input phases be correct | ||||||||
| Over-temperature | Cut-off output, charger recovers when temperature lowers to normal range | ||||||||
| CHARGING CONFIGURATION & STANDARD | |||||||||
| Output sockets(Pieces) | / | ||||||||
| Charge cable length(m) | / | ||||||||
| Communication protocol standard | GB/T 27930 - 2015, NB/T33003 - 2010 | ||||||||
| Charge standard | GB/T 33001 - 2010, NB/T33008.1 - 2013 | ||||||||
| CONDITON | |||||||||
| Work temperature | _20 ~ 50 ℃ | ||||||||
| Storage temperature | _40 ~ 80 ℃ | ||||||||
| Relative humidity | < 95% non condense | ||||||||
| Atmosphere pressure(kpa) | 70 ~ 106 | ||||||||
| PHYSICAL | |||||||||
| Size(W*D*H)mm | 600*600*1600 | 600*600*2000 | |||||||
| N.Weight(kg) | < 170 kg | < 270 kg | |||||||
|
|||||||||
More Products